South-Facing Meteorological Met Station with relative humidity, air temp, incoming shortwave radiation, soil moisture, rain gage and barometric pressure.
GGL_SF_Met is a 2.5 m multi parameter meterological tripod representing south facing aspects of Gordon Gulch.
Query page here: https://bcczo.colorado.edu/query/ggl-sf-met.shtml
See related for GGL_NF_Met (Gordon Gulch Lower South Facing Met Station)
Sensor ID and descriptions-
GGL_Met_SF, Communication, Campbell Scientific CR 1000 s/n 36604, Vaisala Barometer PTB110 s/n D0850005 replaced on 7/12/15 with serial number L2750359 voltage range 0-2.5vdc, Li Cor 200x Pyranometer s/n PY58515, REBS Q-7.1 Net Radiometer s/n Q10011 pos. calibration factor 8.94, negative calibration factor 11.04, replaced 20161110 with Kipp and Zonnen NR-Lite-2 sn# 160888 calibration factor 15.4, calibrated 5/11/2016, due 2 years 5/11/2018, Campbell Scientific T-107 Temperature Probe s/n CZOT_017
Campbell Scientific T-107 Temperature Probe s/n CZOT_013, replaced with Vaisala HMP-60 Temp and RH, serial M3141020 unsure of calibration due date, RMYoung03101 L wind speed s/n CZOwind01, replaced with same instrument, send back for calibration, Campbell Scientific CS616 s/n CZOvw017, replaced 7/7/16 w CS-616 s/n czovw14, Texas Electronics tipping bucket s/n 45911-208,replaced 7/7/16 with Texas Instruments TR-525mm 45910-208, 10 w solar panel, Campbell Scientific RF401a spread spectrum radio serial # 2663, 3-9amp per hour batt., MorningStar Sunsaver 6, Modem Airlink LS300, 9db yagi style antennae, TR-525mm serial 45910-208, remove 22 cm vwc CS-616 no visible serial and replace with CS-616 serial czovw14 ... https://www.hydroshare.org/resource/d66f1f3239a94c7682c71217b1a94e0b